Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 54
Filtrar
5.
J Pediatr Ophthalmol Strabismus ; 60(3): 196-202, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35758197

RESUMO

PURPOSE: To evaluate retinal nerve fiber layer (RNFL) thickness in children with migraine, with and without aura, compared to healthy controls using optical coherence tomography (OCT). METHODS: In this cross-sectional case-control study, patients with a diagnosis of migraine with aura (MwA) or without aura (MwoA) were considered and healthy children were included as controls. Age, sex, duration of migraine, number of episodes per month, duration of episodes, and use of prophylactic treatment with magnesium were recorded. All patients underwent complete ophthalmologic, neurologic, and pediatric examination. Optic nerve OCT images were obtained using Heidelberg Spectralis OCT (Heidelberg Engineering) and mean global RNFL thickness and the average thickness for each sector were noted. RESULTS: Thirty-seven children were included: 17 with migraine (9 MwoA and 8 MwA) and 20 controls, the mean age being 13.8 ± 2.9 (range: 8 to 16) and 13.4 ± 2.5 (range: 7 to 16) years, respectively. No significant differences in RNFL thickness were found when comparing all patients who had migraine with healthy controls. However, children with MwA showed statistically significant reductions in RNFL thickness in the temporal (mean difference: 7.83; 95% CI: 0.52 to 15.14, P = .027) and inferior-temporal (mean difference: 16.06; 95% CI: 1.95 to 30.16, P = .027) sectors compared to patients with MwoA. None of the other sectors showed statistically significant differences between groups (all P > .05). In the migraine group, negative correlations were detected between the number of episodes per month and RNFL thickness in the nasal-superior quadrant (r = -.420; P = .021). CONCLUSIONS: Children with MwA may present a decrease in RNFL thickness, which is associated with the number of episodes per month. [J Pediatr Ophthalmol Strabismus. 2023;60(3):196-202.].


Assuntos
Epilepsia , Transtornos de Enxaqueca , Enxaqueca com Aura , Humanos , Criança , Adolescente , Tomografia de Coerência Óptica/métodos , Células Ganglionares da Retina , Estudos de Casos e Controles , Estudos Transversais , Fibras Nervosas , Enxaqueca com Aura/diagnóstico
8.
J Neuroophthalmol ; 42(1): e217-e224, 2022 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-34001737

RESUMO

BACKGROUND: Hemianopias can have a severe impact on functional ability and quality of life (QoL). Binocular visual field (VF) analysis is clinically more relevant to visual function than monocular VF. The aim is to analyze the binocular VF of patients with hemianopias and its association with the monocular VF and to assess the QoL of these patients through questionnaires specifically related to vision compared with healthy controls. METHODS: The case-control study included patients with hemianopias and controls. Sex, age, general history, etiology, location of the lesion, and time since the lesion appeared were recorded. Monocular VF and Esterman binocular VF were performed. VF defect, mean defect (MD), and Esterman scores were recorded. Visual Activities Questionnaire (VAQ-33) and Visual Function Questionnaire (VFQ-25) questionnaires were administered. RESULTS: Twenty patients with hemianopia and 22 healthy controls were included. The Esterman score in homonymous hemianopia patients (n = 17) correlated with best eye MD (r = -0.62, P = 0.01), worst eye MD (r = -0.70, P = 0.002), and average MD (r = -0.68, P = 0.003). Compared with healthy control subjects, patients with homonymous hemianopia had significantly lower VFQ-25 score and in 10/12 subscales (all P < 0.001). VAQ-33 scores revealed lower overall and subscales scores with the exception of light/dark adaptation (P = 0.08). Correlations were found between monocular and binocular VF scores and general vision (r = -0.55), peripheral vision (on both questionnaires, r-range -0.75 to 0.47), VFQ-25 and VAQ-33 overall scores (r = -0.59, -0.49 and 0.50), and glare disability (r = 0.53 and 0.67). CONCLUSIONS: Hemianopic VF defects involve a major alteration in the patients' vision-related QoL.


Assuntos
Hemianopsia , Campos Visuais , Estudos de Casos e Controles , Hemianopsia/diagnóstico , Humanos , Qualidade de Vida , Inquéritos e Questionários , Transtornos da Visão , Visão Binocular , Testes de Campo Visual
9.
Eur J Ophthalmol ; 32(6): NP91-NP94, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34231401

RESUMO

PURPOSE: To describe optical coherence tomography angiography (OCTA) findings in the retina and choroid of patients with neurofibromatosis type 1 (NF1). METHODS: We describe a series of four patients diagnosed with NF1 and choroidal nodules who underwent a comprehensive ophthalmic evaluation including a retinal multimodal imaging study based on retinography, near-infrared reflectance imaging (NIR), enhanced depth imaging (EDI) optical coherence tomography (OCT) and OCTA. RESULTS: Patients were three women and one man aged 36-47 years. In all patients, the choroidal nodules were not visible in retinographies but easily detectable with NIR, appearing as multiple bright patches. On OCTA, we observed reduced vessel density in the choriocapillaris in zones where choroidal nodules appeared in OCT images. In one patient, a corkscrew vessel was visible in the superficial capillary plexus. CONCLUSION: Choriocapillaris vessel density was reduced in zones where choroidal nodules occur in NF1 patients. Further work is needed to clarify the clinical relevance of this finding.


Assuntos
Doenças da Coroide , Neurofibromatose 1 , Corioide/irrigação sanguínea , Doenças da Coroide/diagnóstico , Feminino , Angiofluoresceinografia/métodos , Humanos , Masculino , Neurofibromatose 1/complicações , Neurofibromatose 1/diagnóstico , Tomografia de Coerência Óptica/métodos
10.
Cureus ; 13(11): e19788, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-34956781

RESUMO

Objective Following nerve injury, the projection of posterior visual pathway lesions into the macular ganglion cell layer (GCL) region indicates retrograde trans-synaptic degeneration (RTSD) as a mechanism of functional damage. Our purpose is to assess GCL damage and the impacts of ischemic brain lesions affecting the visual pathway on macular microvascularization in patients with stroke. Methods In a case-control study, we examined 15 ischemic stroke patients who showed visual field defects and 50 healthy controls using the high-resolution optical coherence tomography (OCT) techniques such as spectral domain-OCT (SD-OCT) to measure retinal nerve fiber layer (RNFL) and GCL thicknesses, and OCT angiography (OCTA) to assess damage to the macular microvasculature. Results In the cases, the correlation was detected among the site of vascular damage, visual field defect, retinal GCL thinning, and normal RNFL thickness. Further observations were significant reductions in macular thickness, GCL thickness, outer retinal layer vascular density, and vascular area in deeper retinal layers (p < 0.05). Conclusion Our findings suggest that ocular microvasculature abnormalities could serve as diagnostic and/or prognostic markers in patients with stroke and support the described use of GCL thickness as an image marker of visual pathway RTSD after brain injury.

11.
Case Rep Ophthalmol ; 12(3): 773-777, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34720976

RESUMO

The purpose is to study for the first time the vascular plexuses and the retinal nerve fiber layer and raphe of a patient with a very uncommon anatomical variation: an anomalous retinal artery supplying the whole macula. We used multimodal imaging, en face spectral-domain optic coherence tomography, and spectral-domain optic coherence tomography angiography. One patient presented in his left eye a very unusual anatomical variation of macular vascularization. A retinal artery deriving from the inferior temporal retinal artery irrigated the whole macula. The formation of the papillomacular bundle and the temporal raphe nerve fiber layer has been attributed to the earlier development of the central retina and to the existence of 2 distinct watershed zones. However, there are very uncommon anatomical variations of the retinal vasculature in which large retinal vessels cross the raphe and could influence the morphology and structure of the nerve fiber layer of the posterior pole. We review the literature on the subject and document for the first time an anomalous artery that irrigates the whole macula, normal thickness and morphology of the nerve fiber layer, and the temporal raphe.

12.
Can J Ophthalmol ; 56(6): 364-370, 2021 12.
Artigo em Inglês | MEDLINE | ID: mdl-33577755

RESUMO

OBJECTIVE: To describe corneal densitometry, topographic measurements, and biomechanical properties in patients with primary congenital glaucoma (PCG) and healthy patients. To examine correlations between variables and determine their glaucoma diagnostic capacity. METHODS: This was a cross-sectional, case-control study conducted in 50 eyes of 50 patients with PCG (G1) and 40 eyes of 40 healthy patients (G2). The variables determined in each participant were: intraocular pressure, best corrected visual acuity (BCVA), corneal densitometry, topographic data using the Pentacam HR-Scheimpflug imaging system (Oculus Optikgerate GmbH, Wetzlar, Germany), and corneal hysteresis (CH) and corneal resistance factor (CRF) using the Ocular Response Analyzer (Reichert Ophthalmic Instruments, Depew, NY). RESULTS: Overall densitometry was significatively higher in the PCG group (G1: 17.94 ± 4.99 vs G2: 13.25 ± 1.96, p < 0.001). CH (G1: 8.02 ± 11.35 vs G2: 11.35 ± 1.42, p < 0.001) and CRF (G1: 9.48 ± 2.83 vs G2: 10.77 ± 1.34, p < 0.001) were lower in the glaucoma group. Mean posterior, central, and anterior elevation and mean keratometry were higher in G1 (p < 0.05). In the PCG group, overall densitometry showed significant correlation with CH (r = -0.321, p = 0.028) and with BCVA (r = -0.498, p = 0.002). AUCs (areas under the curve) for CH and overall densitometry were high (0.839 and 0.899 respectively) and the best overall densitometry; CH and CRF cutoffs were 14.0, 9.3 and 9.2 respectively. CONCLUSION: Densitometry is increased, and biomechanical corneal properties are decreased in patients with PCG. Densitometry and visual acuity showed a negative and significant correlation, so this measurement could be used as an indirect parameter of BCVA in the clinical practice.


Assuntos
Córnea , Glaucoma , Fenômenos Biomecânicos , Estudos de Casos e Controles , Estudos Transversais , Densitometria , Glaucoma/diagnóstico , Humanos , Pressão Intraocular , Tonometria Ocular
13.
Acta Ophthalmol ; 99(6): 663-668, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-33354920

RESUMO

PURPOSE: To examine agreement between intraocular pressure (IOP) measurements made using the rebound tonometer Icare ic200 (RT200) and the Perkins handheld applanation tonometer (PAT) in patients with primary congenital glaucoma (PCG). The impacts of several covariables on measurements using the two devices were also assessed. MATERIALS AND METHODS: Intraocular pressure measurements were made in a single session in 86 eyes of 86 patients with PCG (46 under anaesthesia, 40 in the office). The order was RT200 then PAT. The variables age, central corneal thickness (CCT), corneal state and anaesthesia were recorded in each patient. Data were compared by determining interclass correlation coefficients (ICC) for each tonometer and representing the differences detected as Bland-Altman plots. Effects of covariables were assessed through univariate and multivariate regression. RESULTS: Mean IOP difference between tonometers (RT200 minus PAT) was 1.26 mmHg (95%: 0.22-2.31). Absolute agreement (ICC) was 0.73 (95% CI: 0.62-0.82). Lower and upper limits of agreement (95%) were -8.06 mmHg (95% CI: -9.87 to -6.25) and 10.59 mmHg (95% CI: 8.77-12.40), respectively. The tonometers showed systematic differences (a = -4.63 mmHg; 95% CI: -9.11 to -1.44) and proportional differences; for each mmHg increase in PAT-IOP, the RT200 reading increased by 1.28 mmHg (b = 1.28; 95% CI: 1.12-1.53). None of the variables tested as predictors were able to explain differences between the tonometers. CONCLUSIONS: Despite the good overall agreement between both tonometers, caution should be taken in high values of IOP, considering the interchangeability of its readings as systematic and proportional differences appear to exist between both methods.


Assuntos
Glaucoma/fisiopatologia , Pressão Intraocular/fisiologia , Tonometria Ocular/métodos , Criança , Pré-Escolar , Estudos Transversais , Feminino , Glaucoma/congênito , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes
14.
Headache ; 60(8): 1697-1704, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32666513

RESUMO

BACKGROUND: Series of patients with SARS-CoV-2 infection report headache in 6%-15% of cases, although some data suggest that the actual frequency is higher, and that headache is not associated with fever. No study published to date has analyzed the characteristics of headache in these patients. OBJECTIVE: To analyze the characteristics of COVID-19 related headaches. METHODS: We conducted a survey of Spaniard healthcare professionals who have been infected by SARS-CoV-2 and presented headache during the course of the disease. The survey addressed respondents' medical history and headache characteristics, and we analyzed the association between both. RESULTS: We analyzed the responses of a sample of 112 healthcare professionals. History of migraine was reported by 20/112 (17.9%) of respondents, history of tension-type headache by 8/112 (7.1%), and history of cluster headache was reported by a single respondent; 82/112(73.2%) of respondents had no history of headache. Headache presented independently of fever, around the third day after symptom onset. The previous history of migraine was associated with a higher frequency of pulsating headache (20% in patients with previous migraine vs 4.3% in those with no history of migraine, P = .013). CONCLUSION: Headache is often holocranial, hemicranial, or occipital, pressing, and worsens with physical activity or head movements. Because the characteristics of the headache and the associated symptoms are heterogeneous in our survey, we suggest that several patterns with specific pathophysiological mechanisms may underlie the headache associated with COVID-19.


Assuntos
COVID-19/epidemiologia , Cefaleia/epidemiologia , Pessoal de Saúde , SARS-CoV-2 , Adulto , COVID-19/complicações , Comorbidade , Estudos Transversais , Diabetes Mellitus/epidemiologia , Dislipidemias/epidemiologia , Feminino , Gastroenteropatias/etiologia , Cefaleia/classificação , Transtornos da Cefaleia Secundários/diagnóstico , Transtornos da Cefaleia Secundários/epidemiologia , Transtornos da Cefaleia Secundários/etiologia , Humanos , Hipertensão/epidemiologia , Masculino , Pessoa de Meia-Idade , Transtornos de Enxaqueca/epidemiologia , Doenças Profissionais/epidemiologia , Pandemias , Equipamento de Proteção Individual , Prevalência , Transtornos das Sensações/etiologia , Espanha/epidemiologia , Inquéritos e Questionários , Cefaleia do Tipo Tensional/epidemiologia
15.
Eur J Ophthalmol ; 30(3): 525-532, 2020 May.
Artigo em Inglês | MEDLINE | ID: mdl-30957520

RESUMO

OBJECTIVE: To assess incidence and risk factors of cataract extraction in patients with primary congenital glaucoma, surgical outcome, and complications. MATERIAL AND METHOD: Retrospective cohort study, in which 108 patients with primary congenital glaucoma were included. Data collected were need for cataract extraction and at what age, intraocular pressure at diagnosis of primary congenital glaucoma, required antiglaucomatous surgeries, possible mutation in the CYP1B1 gene, and final visual acuity. Among the patients who required cataract extraction were visual acuity, intraocular pressure, and complications, evaluated preoperatively and postoperatively. The data were analysed with STATA. RESULTS: A total of 198 eyes of 108 patients were included, with a median follow-up of 8 years (range: 5-53). In all, 32 eyes (16.2%) of 24 patients (22%) required cataract extraction. The median age for cataract extraction was 12.94 years (interquartile range: 2.42-22). The main identified risk factors associated with cataract extraction were antiglaucomatous surgeries (hazard ratio 1.48, p < 0.001) and valvular implant (hazard ratio 2.78, p < 0.001). Lens was implanted in 30/32 eyes and the main complications were intraocular pressure decontrol (n = 13), capsular fibrosis (n = 7), corneal decompensation (n = 4), lens subluxation (n = 4), and endophthalmitis (n = 1). Visual acuity improvement was observed after cataract extraction in 66.67% of eyes. CONCLUSIONS: There is a high incidence of cataract surgery in patients with primary congenital glaucoma, but generally outside of pediatric age. A greater risk of cataract extraction was identified in those patients with a greater number of antiglaucomatous surgeries, especially after valvular implantation. Despite the high rate of complications related to cataract extraction in primary congenital glaucoma, good visual improvement was observed after surgery.


Assuntos
Extração de Catarata/estatística & dados numéricos , Catarata/epidemiologia , Hidroftalmia/complicações , Adolescente , Adulto , Criança , Pré-Escolar , Citocromo P-450 CYP1B1/genética , Feminino , Seguimentos , Humanos , Hidroftalmia/genética , Hidroftalmia/cirurgia , Incidência , Lactente , Pressão Intraocular/fisiologia , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Fatores de Risco , Tonometria Ocular , Acuidade Visual/fisiologia
17.
Rev. esp. cardiol. (Ed. impr.) ; 71(7): 553-564, jul. 2018. tab, graf
Artigo em Espanhol | IBECS | ID: ibc-178581

RESUMO

En los últimos años, el número de pacientes anticoagulados y antiagregados está aumentando significativamente. Al ser un tratamiento crónico, es de esperar que a lo largo de su vida necesiten un procedimiento quirúrgico o intervencionista que pueda requerir la interrupción del fármaco antitrombótico. La decisión de retirar o mantener dicho tratamiento estará determinada, por un lado, por el riesgo trombótico y, por otro, por el hemorrágico. De la interacción entre estos 2 factores dependerá la actitud ante la anticoagulación y la antiagregación. El objetivo de este documento de consenso, coordinado desde el Grupo de Trabajo de Trombosis Cardiovascular de la Sociedad Española de Cardiología y certificado por un amplio número de sociedades científicas que participan en el proceso asistencial del paciente durante el periodo perioperatorio o periprocedimiento, consiste en proponer una serie de recomendaciones prácticas y sencillas con el fin de homogeneizar la práctica clínica diaria


During the last few years, the number of patients receiving anticoagulant and antiplatelet therapy has increased worldwide. Since this is a chronic treatment, patients receiving it can be expected to need some kind of surgery or intervention during their lifetime that may require treatment discontinuation. The decision to withdraw antithrombotic therapy depends on the patient's thrombotic risk versus hemorrhagic risk. Assessment of both factors will show the precise management of anticoagulant and antiplatelet therapy in these scenarios. The aim of this consensus document, coordinated by the Cardiovascular Thrombosis Working Group of the Spanish Society of Cardiology, and endorsed by most of the Spanish scientific societies of clinical specialities that may play a role in the patient-health care process during the perioperative or periprocedural period, is to recommend some simple and practical guidelines with a view to homogenizing daily clinical practice


Assuntos
Humanos , Trombose/prevenção & controle , Fibrinolíticos/administração & dosagem , Anticoagulantes/administração & dosagem , Inibidores da Agregação Plaquetária/administração & dosagem , Tromboembolia/prevenção & controle , Período Perioperatório , Suspensão de Tratamento , Padrões de Prática Médica
18.
Rev Esp Cardiol (Engl Ed) ; 71(7): 553-564, 2018 Jul.
Artigo em Inglês, Espanhol | MEDLINE | ID: mdl-29887180

RESUMO

During the last few years, the number of patients receiving anticoagulant and antiplatelet therapy has increased worldwide. Since this is a chronic treatment, patients receiving it can be expected to need some kind of surgery or intervention during their lifetime that may require treatment discontinuation. The decision to withdraw antithrombotic therapy depends on the patient's thrombotic risk versus hemorrhagic risk. Assessment of both factors will show the precise management of anticoagulant and antiplatelet therapy in these scenarios. The aim of this consensus document, coordinated by the Cardiovascular Thrombosis Working Group of the Spanish Society of Cardiology, and endorsed by most of the Spanish scientific societies of clinical specialities that may play a role in the patient-health care process during the perioperative or periprocedural period, is to recommend some simple and practical guidelines with a view to homogenizing daily clinical practice.


Assuntos
Anticoagulantes/uso terapêutico , Fibrinolíticos/uso terapêutico , Hemorragia/etiologia , Inibidores da Agregação Plaquetária/uso terapêutico , Tromboembolia/etiologia , Idoso , Idoso de 80 Anos ou mais , Substituição de Medicamentos , Feminino , Hemorragia/prevenção & controle , Humanos , Cuidados Intraoperatórios/métodos , Masculino , Cuidados Pré-Operatórios/métodos , Medição de Risco , Fatores de Risco , Tromboembolia/prevenção & controle
19.
Can J Ophthalmol ; 53(3): 236-241, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29784159

RESUMO

OBJECTIVE: This study was designed to assess changes in corneal topography and biomechanics after intraocular pressure (IOP) monitoring using the Triggerfish contact lens sensor (CLS). METHODS: For this prospective study, 30 eyes of 30 subjects: 14 healthy subjects (G1) and 6 glaucoma patients (G2), were recruited for 24 hours of continuous IOP monitoring using the CLS. The following measurements were taken before CLS fitting and after lens removal: maximum keratometry (Kmax), mean keratometry (MK), and corneal astigmatism (Cyl) measured through Pentacam corneal topography, and the corneal biomechanical variables corneal hysteresis (CH) and corneal resistance factor (CRF) measured with the Ocular Response Analyzer (ORA). RESULTS: Pentacam data revealed significant changes after CLS removal in Kmax (+3.14 ± 2.46 D, p = 0.002), MK (+0.52 ± 0.63 D, p = 0.02), and Cyl (+0.48 ± 0.53 D, p = 0.019) in G1; and Kmax (+1.38 ± 1.43 D, p = 0.002) in G2. The changes observed were more pronounced in G1 than in G2 but differences were not significant. The ORA results indicated higher CH (11.35 ± 2.42 vs 8.17 ± 2.09) and CRF (10.3 ± 2.03 vs 9.1 ± 1.81) before lens fitting in G1 than G2, while no significant changes were produced after CLS removal in either group. CONCLUSIONS: The use of CLS for IOP monitoring over 24 hours caused topographic changes in both healthy subjects and glaucoma patients. No changes were produced in corneal biomechanics.


Assuntos
Lentes de Contato , Córnea/fisiopatologia , Glaucoma de Ângulo Aberto/fisiopatologia , Pressão Intraocular/fisiologia , Monitorização Fisiológica/instrumentação , Tonometria Ocular/instrumentação , Transdutores de Pressão , Adulto , Fenômenos Biomecânicos , Córnea/diagnóstico por imagem , Topografia da Córnea , Desenho de Equipamento , Feminino , Seguimentos , Glaucoma de Ângulo Aberto/diagnóstico , Humanos , Masculino , Estudos Prospectivos , Reprodutibilidade dos Testes , Adulto Jovem
20.
Int J Ophthalmol ; 10(10): 1521-1527, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-29062770

RESUMO

AIM: To determine the effects of peripheral corneal thickness (PCT) on dynamic contour tonometry(DCT) and Goldmann applanation tonometry (GAT). METHODS: A cross-sectional study. We created a software which calculates the corneal contour (CC) as a function of the radius from the corneal apex to each pixel of the contour. The software generates a central circumference with a radius of 1 mm and the remainder of the cornea is segmented in 5 rings concentric with corneal apex being its diameter not constant around the corneal circumference as a consequence of the irregular CC but keeping constant the diameter of each ring in each direction of the contour. PCT was determined as the mean thickness of the most eccentric ring. Locally weighted scatterplot smoothing (LOWESS) regression was used to determine the pattern of the relationship between PCT and both DCT and GAT respectively. Thereafter, two multivariable linear regression models were constructed. In each of them, the dependant variable was intraocular pressure (IOP) as determined using GAT and DCT respectively. In both of the models the predictive variable was PCT though LOWESS regression pattern was used to model the relationship between the dependant variables and the predictor one. Age and sex were also introduced control variables along with their first-degree interactions with PCT. Main outcome measures include amount of IOP variation explained through regression models (R2) and regression coefficients (B). RESULTS: Subjects included 109 eyes of 109 healthy individuals. LOWESS regression suggested that a 2nd-degree polynomial would be suitable to model the relationship between both DCT and GAT with PCT. Hence PCT was introduced in both models as a linear and quadratic term. Neither age nor sex nor interactions were statistically significant in both models. For GAT model, R2 was 17.14% (F=9.02; P=0.0002), PCT linear term B was -1.163 (95% CI: -1.163, -0.617). PCT quadratic term B was 0.00081 (95% CI: 0.00043, 0.00118). For DCT model R2 was 14.28% (F=9.29; P=0.0002), PCT linear term B was -0.712 (95% CI: -1.052, -0.372), PCT quadratic term was B=0.0005 (95% CI: 0.0003, 0.0007). CONCLUSION: DCT and GAT measurements are conditioned by PCT though this effect, rather than linear, follows a 2nd-degree polynomial pattern.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...